Sunset Theatre



DateTimeOutsideRoofLobbyTheatreBasementHopperNotes
TempSnowpackTempTempTempstatus
29/10/0913:230++Light7c7c10cPlayed w thermostat for an hour but could not get working properly
30 10/0918:278clight-8c9.5c-Did not use furnace - thermostat did not work. Brought one from home
31/10/0910:470+++clear7c8c9c-Installed thermostat - confirmed active - confirmed pilot cycle - furnace on at 11:43
31/10/0913:020+++clear7c1011-fan is off - thermostat works - about 1/4 bag gone
31/10/0916:190+++clear7c10.511-Down about 1/2 bag
31/10/0919:530clear121111.5-down 3/4 bag - Will leave on over night
31/10/0921:300clear121111-down 1 bag - chicken. Shut down furnace - Will start tomorrow
01/11/0908:540light10.49101 bagStarted furnace - filled hopper to top level
01/11/0915:340+clear12.41111-used about 1/2 bag
01/11/0920:410-clear12.31212-down about 3/4 bag - furnice on over night
02/11/0907:233clight12.712121 1/4 bagno obvious problems over night
02/11/0910:040clight13.41313-down 1/2 to 3/4 bag. Tried setting thermostat down a bit
03/11/0909:20-2light13.312.5131 1/2 bagmod thermostat to work at lower temp
03/11/0921:00-clear18.91822-Furnace off - need to fix thermostat
04/11/0910:250cclear11.91012--



DateTimeOutsideRoofLobbyTheatreBasementHopperNotes
TempSnowpackTempTempTempstatus
05/11/0912:250++clear11.1910c2 bagsNew thermostat set to 7.5c
05/11/0919:230+clear12.51211-Down 1/4 bag - set to 5c
06/11/0908:33-1light13.413131 bagDont understand - Electric heaters? off now - 8 min cycle? Thermostat to bottom - checking how much fuel by time I come back
06/11/0916:370light14.11314-Down 1/4 bag - Fan on - thermostat at bottom - I think that pilot is keeping heat up (8 min cycle)
07/11/0909:1414clear13.21313.51 1/3 bag keeps blowing too hot - Thermostat set to 5c See notes above
08/11/0908:40-7light10.98112/3 bagThermostat set to 5c
08:11:0921:38-2light10.58.59-Down 1/4 bag approx. Furnace is blowing. Thermostat at 5c
09/11/0907:43+2clear10.0883/4 bag-
09/11/0921:03-32”10.089-down 1/4 bag approx
10/11/0911:160mostly clear10.4893/4 bag-
10/11/0922:02-4light10.48.59-Down 1/4 bag - everything good
11/11/0908:23-43”10.36.591/2 bag-
11/11/0922:52-14light10.289-down 3/4 bag
12/11/0907:53-16light9.7791 bagJust under 1 - Slightly over full
12/11/0921:48-14light9.879--


05/11/09 - replaced thermostat with one that dials down lower (has 5c on scale) - running furnace - will check tonight.
07/11/09 - Furnace uses 1 1/3 bag on 8 minute cycle with thermostat off and no other heat source in basement or theatre and maintains 13 degree c. in 0 degree outside temp - need to play with 16 minute cycle to see if pilot will go out in that time. 09:28 - feed active & switched to 16 min cycle. 09:44 feed system on - seems OK. Furnace blower did not come on. Will check later / checked @ 15:00 - Temp dropping - not much fuel used.


DateTimeOutsideRoofLobbyTheatreBasementHopperNotes: thermostat@5 - Pilot@16 min.- Draft fan on med.
TempSnowpackTempTempTempstatus
13/11/0909:24-5light9.7791 bagSlightly overfull
13/11/0921:21-132”9.479-Down 1/4 bag approx
14/11/0909:48-92-3”9.36.591 bagSame as yesterday - Slightly overfull
14/11/0921:21-49.77.58--
15/11/0909:22-24”9.47.591 bagfill to level
15/11/0922:26+3top clear9.689--
16/11/0909:42-12-3”9.9893/4 bag-
17/11/0909:40+2almost clear10893/4 bagTap water is cool not cold
17/11/0920:56-59.789-Down 1/4 bag - fan coming on (blower) from resid. heat
18/11/0909:2009.5791/2 bag+ slightly over 1/2 bag
18/11/0920:11-39.789-windey
19/11/0909:581clear9.778.53/4 bagCall from Ron re: smoke - Was pilot coming on
20/11/0909:153clear9.2781/2 bagFurnice out - cleaned - re-lit
20/11/0920:26-2clear9.888.5--
21/11/0907:51-7light9.7783/4 baglightly snowing
21/11/0920:58-9light9.678--



DateTimeOutsideRoofLobbyTheatreBasementHopperNotes: thermostat@5 - Pilot@16 min.- Draft fan on med.
TempSnowpackTempTempTempstatus
22/11/0910:27-42-3”9.3783/4 bagFurnice out again - cold enough went to 8 min pilot. Will use more fuel - wasent out for long
22/11/0918:22-43-4”10.28.59-Down 3/4 bag
23/11/0910:21-34”119.5101 1/2 bag8 min cycle - double what 16 min cycle used. Wish 12 min cycle.
23/11/0920:46-35”11.21010--
24/11/0908:57-15light11.310101 1/4 bagthermostat not active. set at 5. triggers about 8
24/11/0919:59-311.4910--
25/11/0907:4011/2 clear raining11.810101 1/4 bag-
25/11/0921:335clear12.71212--
26/11/0911:402clear13.613121 1/2 bagchanged to 16 min pilot-if it goes out I’ll light it tonight
26/11/0922:01-7clear12.31111-left on 16 min cycle (still working)
27/11/0907:53-12light10.99.5113/4 bag16 min seems to be working
27/11/0920:31-6light10.68.510--
28/11/0911:52-32”10.0883/4 bagthermostat coming on in this corner of the basement
28/11/0920:56-24-5”10.288--
29/11/0907:08-24-5”east10.4883/4 bagsnow clear on west side - sliding on east
29/11/0922:16-2snowing about 5”10.799-Snowing - 6” since morning



DateTimeOutsideRoofLobbyTheatreBasementHopperNotes: thermostat@5 - Pilot@16 min.- Draft fan on med.
TempSnowpackTempTempTempstatus
30/11/0909:07-54-5” sliding9.8881/2 bagpower out 12:30 AM-5:30 Am - cleaned and relit - thermostat on - 8 min cycle for morning - checked 10:56 - OK
30/11/0920:21-84” sliding10.288-Set to 16 min cycle
1/12/0908:45-179.5783/4 bag-
1/12/0920:13-179.579-thermostat still at 5 - does not seem to be controling furnice - set to 8 min cycle
2/12/0908:23-219.6781 1/4 bagfurnice on light working - thermostat active - I had reset furnice yesterday & probably corrected problem
2/12/0920:28-168.488-left on 8 min cycle
3/12/0910:10-1210.27.581 1/2 bagwent to 16 min cycle - thermostat appears to be working - on/off light working
3/12/0920:03-710.078--
4/12/0908:39-109.77.083/4 bagSnow sliding from top and not building up - used all pellets in bathroom area
4/12/0921:35-1310.189--
5/12/0909:05-23much the same9.9891 1/2 bag-
5/12/0918:53-169.479--
6/12/0908:21-259.2791 1/4 bagsnow starting to build up but still only about 5” on bottom
6/12/0918:14-249.879--
7/12/0908:44-279.4792 bagsSlightly over full - needs cleaning - maybe tonight
7/12/0920:23-209.479--